SDAS215A - APRIL 1982 - REVISED DECEMBER 1994
These data selectors/multiplexers contain full binary decoding toselect one-of-eight data sources and feature controlled complementary3-state outputs.
The 3-state outputs can interface with and drive data lines ofbus-organized systems. With all but one of the common outputsdisabled (at the high-impedance state), the low impedance of thesignal-enabled output drives the bus line to a high or low logiclevel. Both outputs are controlled by the output-enable (OE\) input.The outputs are disabled when
is high.
The SN54ALS251 is characterized for operation over the fullmilitary temperature range of -55°C to 125°C. TheSN74ALS251 is characterized for operation from 0°C to 70°C.
D0, D1,...D7 = the level of the respective D input
View more information about generic part numbers:SN54ALS251, SN74ALS251
Go to the Engineering Design Center to locate information on other TI Semiconductor devices.