.mem_config
The memory configuration table outlines the network components and
where they should be loaded.  To conserve conventional memory (RAM)
some of the network components may be loaded into expanded (EMS) or
extended (XMS) memory if it is available.  Note that performance may
be adversely affected by loading the components into EMS or XMS.\n
\n
The current values are highlighted.  The default values are as 
follows:\n
\n
	            Network\n
	            Component		Default\n
	            ---------		-----------\n
	            LAD      		RAM\n
	            LAST     		RAM\n
	            DNP      		RAM\n
	            REDIR    		RAM\n
	            LAT      		Don't load\n
	            RCV      		Don't load\n
	            CTERM    		Don't load\n
	            NML      		Don't load\n
\n
If the workstation has extended memory, and you choose to load REDIR into 
XMS, NETSETUP will modify the CONFIG.SYS to load HIMEM.SYS.  Any other 
XMS drivers should be loaded after HIMEM.SYS.
.end_help

.ems_help
If the workstation has expanded memory and an Expanded Memory Manager 
(EMM) driver installed select YES.  Otherwise select NO.  This allows 
NETSETUP to check whether or not a memory configuration is valid.\n
\n
NOTE: If you select YES, the EMM driver should already be installed. 
NETSETUP will not modify the CONFIG.SYS to load the driver.  If you 
try to load the network components into EMS and the driver is not 
installed, they will be loaded into conventional memory instead.
.end_help

.xms_help
If the workstation has extended memory select YES.  Otherwise select
NO.  This allows NETSETUP to check whether or not a memory
configuration is valid.\n
\n
NOTE: If you select YES, NETSETUP will not modify the CONFIG.SYS to
load HIMEM.SYS unless you choose to load the redirector into
extended memory.\n
\n
Loading HIMEM.SYS will fail if you do not have extended memory.
.end_help

.config_type
Select "Local boot" if the key diskette will be a floppy diskette or
a hard disk partition.  Choose "Remote boot" if you wish to create,
modify, or remove a network key diskette.  A network key diskette is
used when booting from the server.\n
\n
If you choose "Local boot" you will need a formatted system diskette 
or hard disk partition.  If you have not formatted the diskette, yet, 
you may do so now by exiting NETSETUP or shelling to DOS.  To exit 
NETSETUP press the F10 key twice.  When you are finished, restart 
NETSETUP.  To shell to DOS press the F4 key.  When you are finished 
type "exit" and Return, and you will return to NETSETUP where you
left off. 
.end_help

.load_help
Enter the name of the desired workstation template file. The name may
contain the device name and full path of the file.  There is no default 
filename extension.\n 
\n
	Examples:\n
\n
	    ibmat.tpl\n
	    ..\compaq.tpl\n
	    a:\decstast.v30\n
.end_help

.save_help
Enter the name of a file to save the workstation template. The name may
contain the device name and full path of the file.  There is no default 
filename extension.\n 
\n
	Examples:\n
\n
	    ibmat.tpl\n
	    ..\compaq.tpl\n
	    a:\decstast.v30\n
.end_help

.sample
\n
There is no help available for this topic at this time.\n
.end_help

.get_curkb_help
\n
This is a list of countries supported by the LK250, use the arrow keys to
select one and then enter Return. 
.end_help

.getkeycountry_help
\n
This is a list of countries supported by the LK250, use the arrow keys to
select one and then enter Return. 
.end_help

.getcurkeybrd_help
\n
If you do not have an LK250 keyboard, select NO.\n 
\n
If you select YES, NETSETUP will allow you to specify the
country/language of the keyboard. 
.end_help

.askconfigws_help
\n
If you are creating the key diskette for this workstation select "This
workstation."  If you are creating the key diskette for another
workstation select "Another workstation." 
.end_help

.getwsnamenum_help
The node name and node number requested are those of the workstation
for which you want to create the key diskette.\n 
\n
The node name may be up to six characters in length and may contain
alphanumeric characters (A-Z and 0-9) only. At least one character
must be alphabetic.  The node number has two parts: the area number
and the node number. They are separated by a period (.). The area
number may range from 1 to 63.  The node number may range from 1 to
1023.\n 
\n
	ex.     9.923 is valid\n
	       64.234 is invalid\n
\n
These two fields are required.  If you do not know the node name
and node number of the workstation to be configured exit NETSETUP now
by pressing the F10 key twice or shell to DOS by pressing the F4 key. 
.end_help

.getsvnamenum_help
The node name and node number requested are those of a server that you
know is available. This information will be used to create a file
called DECNODE.TXT.\n 
\n
The node name may be up to six characters in length and may contain
alphanumeric characters (A-Z and 0-9) only. At least one character
must be alphabetic.  The node number has two parts: the area number
and the node number. They are separated by a period (.). The area
number may range from 1 to 63.  The node number may range from 1 to
1023.\n 
\n
	ex.     9.923 is valid\n
	       64.234 is invalid\n
\n
Use the up and down arrow keys to move between the two fields.  Use
the left and right arrow keys to move within one of the fields.\n 
\n
NOTE: These two fields are required.  If you do not know the node name
and node number of an available server then exit NETSETUP now by
pressing the F10 key twice. 
.end_help

.getwiretype_help
If the network controller of the workstation is a 3Com 3C501 you must
indicate the type of wiring, thin or thick, used to connect it to the
network.\n
\n
When the key diskette is written, the DLL switches in the file
STARTNET.BAT will be updated with the value chosen here. 
.end_help

.getirq_help
If the network controller of the workstation is either a 3C501 or an IL5010
you must select the Interrupt Request Queue, IRQ. The valid range is from 2
to 7. The default value is 5.\n
\n
When the key diskette is written the DLL switches in the file
STARTNET.BAT will be updated with the value chosen here. 
.end_help

.getmulticast_help
If the network controller of the workstation is either a 3C501 or an
IL5010 you must indicate whether or not multicast should be
disabled.  Disabling multicast will prevent you from receiving 
broadcast messages but may improve performance slightly.\n 
\n
When the key diskette is written the DLL switches in the file
STARTNET.BAT will be updated with the value chosen here. 
.end_help

.getnetworkcard_help
\n
Choose the type of network controller card the workstation has.  If
the controller is listed as "unsupported," memory and performance
benefits may not be the same as those documented for the supported cards.
.end_help

.getsession_help
\n
NETSETUP will load appropriate 
session layer for your 
workstation according to the 
answer of this question.\n
\n
If YES is selected, then 
NETBIOS will be used as session.\n
\n
If NO is selected, then 
NETSESS will be used as session.
.end_help

.getbrdcstrcv_help
\n
If you select YES, the broadcast 
receiver software RCV will be 
loaded.\n
\n
This question is asked only when
multicast is enabled and the 
NETBIOS interface is loaded.
.end_help

.getcfkbcountry_help
\n
Select the country setting to reflect the keyboard of the workstation.
.end_help

.getcfkeybrd_help
If the workstation you wish to configure is using an LK250 keyboard,
then select YES for this question. Otherwise, select NO.\n 
\n
If you select YES, NETSETUP will allow you to specify the
country/language of the keyboard. 
.end_help

.remote_boot_task
You have three choices to configure a remote boot workstation.  They
are as follows:\n 
\n
Create or modify a network key disk:\n
This option allows you to configure a new remote boot workstation or
modify the configuration of an existing workstation.  This option
requires the username and password of a privileged account.  The
account must be on the system on which you are creating or modifying
the network key diskette. You cannot change the Ethernet hardware
address with this option.  To do that choose the "Change an Ethernet
controller" option.\n 
\n
Change an Ethernet controller:\n
This option allows you to change the Ethernet hardware address of an
existing remote boot workstation.  It requires the username and
password of a privileged account.  The account must be on the system
which offers the network key diskette.\n 
\n
Remove a remote boot workstation:\n
This option allows you to remove a network key diskette from the
system.  It requires the username and password of a privileged
account.  The account must be on the system which which offers the
network key diskette. 
.end_help

.modify_network_kd
The hardware address specifies the service name corresponding to the
network key diskette.  Enter the value for the network key diskette
you wish to create or modify.  This option requires the username and
password of a privileged account.  The account must be on the system
on which you are creating or modifying the network key diskette. 
.end_help

.change_ethernet
The old hardware address is used to locate the existing network key
diskette.  When the existing network key diskette is found the
hardware address will be changed to the new value. This option
requires the username and password of a privileged account.  The
account must be on the system which offers the network key diskette.
.end_help

.remove_rb_ws
Enter the Ethernet hardware address of the network key diskette to
be removed.  This option requires the username and password of a
privileged account.  The account must be on the system which which
offers the network key diskette. 
.end_help

.nw_kd_password
\n
\n
The network key diskette selected requires a password.  Enter the
password and Return. 
.end_help

.nw_kd_server
\n
\n
An existing network key diskette could not be found.  Enter the name
of the server on which a new network key diskette should be created. 
.end_help

.nw_kd_size
Select the size of the new network key diskette and enter Return. It
is recommended that you choose the size of a floppy drive on the
workstation for the size of the network key diskette.  If space is a
problem on the system, however, you may choose a smaller size. 
.end_help

.PDSV_node
You may specify a server to which the workstation should first 
attempt to connect for the system service.  If the server is not 
available or the system service is not available on the specified node 
a connection will be made to the first available server.\n
\n
This field is optional.  If you do not wish the workstation to 
connect to a specific server simply enter Return.  The connection 
will be made to the first available server.
.end_help

.initial_workstation
If you are configuring the first workstation you may select YES to
have NETSETUP proceed directly to the workstation profile screen. 
Any field which is not device specific will have been filled with a
default value.\n
\n
If you have not yet run DOSLOAD to create all of the desired DOS
system directories on the system container file,
PCSA$DOS_SYSTEM_V30, select YES to quickly configure a workstation
with minimal network capabilities to make the necessary connections
to run DOSLOAD.\n
\n
If this is not the first workstation or you wish to answer the 
remaining questions select NO.\n
\n
NOTE: In either case you will have a chance to change a field once
the workstation profile screen is displayed. 
.end_help

.getlatsvsize_help
The LAT service table lists the hosts available to SETHOST and the 
MS-Windows VT320 terminal emulators.   The value entered here is used 
to set the /D switch of the LAT layer, which increases the size of the
table.\n
\n
The default value is ten.  Unless you regularly connect to
more than ten hosts simply enter Return.  If you do need to increase
the size of the table enter the new size and Return.\n
\n
If you load LAT into EMS it is recommended that you increase the LAT 
service table size to 700.\n
\n
When the key diskette is written the LAT switches in the file
STARTNET.BAT will be updated with the value chosen here. 
.end_help

.getamtvirdrv_help
This is the number of connections to virtual drives that you want
available to the workstation. The valid range is from 1 to 8.  The
default is 4.\n 
\n
When you are satisfied with the workstation profile and choose to
write the key diskette NETSETUP will modify the CONFIG.SYS to reflect
the number of virtual drives selected, as well as writing the key
diskette.
.end_help

.getdnlnk_help
The number of logical links determines how many network connections
to different DECnet nodes are allowed at one time.  The valid range
is from 1 to 32.  The default is 4.\n
\n
If the workstation will be using the PC DECwindows Display Facility
the minimum number should be eight.  The recommended number is 12.  
The maximum number of logical links should not exceed 15.\n
\n
If you wish to load the DECnet Network Process, DNP, into expanded 
memory, the maximum number of logical links should not exceed 15.\n
\n
When the key diskette is written the file STARTNET.BAT will be updated
with the value chosen here. 
.end_help

.getmaxconn_help
This value is used to configure the maximum number of file and printer
services to which the workstation may connect.  This should be the sum of 
the number of file and printer services.\n 
\n
When the key diskette is written, the redirector, REDIR, switches in the
file STARTNET.BAT will be updated with the value chosen here. 
.end_help

.getprinterbuf_help
These values determine the buffer sizes for the printers connected
as LPT1, LPT2, and LPT3.  A larger buffer may improve printer
performance slightly.  You can save memory by keeping the buffer
size small.\n 
\n
When the key diskette is written, the redirector, REDIR, switches /P1, /P2,
and /P3 in the file STARTNET.BAT will be updated with the values chosen
here. 
.end_help

.askloadmouse_help
If the workstation has a DEPCA Ethernet controller card, and you
wish to load the DEC Mouse driver select YES.  Loading the mouse
driver uses memory.  If you do not use the mouse driver regularly,
you may wish to choose NO.  You may load the mouse driver manually
before running any applications which use a mouse by running
DECMOUSE.COM\n 
\n
If you choose YES, CONFIG.SYS will be updated to load DECMOUSE.SYS,
when the key diskette is written. 
.end_help

.getnonlk250country_help
\n
Select the country type for 
the non-LK250 keyboard that you 
just chose in the previous 
menu.  This information is used 
to load correct keysym file 
in file DWDOS.INI for accessing 
the PC DECwindows Display Facility.
.end_help

.getnonlk250kb_help
\n
Since the configured 
workstation does not use LK250, 
select one of the keyboards 
in the list.  This information 
is used to load correct keysym 
file in file DWDOS.INI for 
accessing the PC DECwindows Display Facility.
.end_help

.getdosutilname_help
Enter the name of the directory on the system service which
corresponds to the DOS running on the workstation.\n
\n
This is the directory name specified in DOSLOAD.  For instance, 
DECstation DOS V3.3 may be in a directory named DSSYSD33.\n
\n
NOTE: DOSLOAD should already have been run to load the various DOS's 
to the system service, PCSA$DOS_SYSTEM_V30.
.end_help

.askloaddosutil_help
If you wish to have the DOS utilities directory from the system
service, PCSA$DOS_SYSTEM_V30, appended to the search path select
YES.  Otherwise, select NO.\n 
\n
NOTE: If the workstation's native DOS has not been loaded to the 
system service using DOSLOAD, select NO.\n
\n
The name of the subdirectory was specified when you ran DOSLOAD. The
directory contains DOS utilities such as BACKUP, CHKDSK, and
FORMAT.\n 
\n
This field is required for remote boot workstations.
.end_help

.getdestdrv_help
\n
This is the letter of the drive where you want your key diskette to be
written. It may be a floppy drive or a hard disk drive.\n
\n
For instance, if the A: drive is a floppy drive, enter "a" and Return.
.end_help

.askstartuptoauto_help
If you select NO, NETSETUP will remove any existing STARTNET or CALL
STARTNET command line from the AUTOEXEC.BAT.  The network must then 
be started by running STARTNET manually.\n
\n
If you select YES, NETSETUP will include the command line STARTNET
or CALL STARTNET at the end of the AUTOEXEC.BAT.  If you wish to
customize the startup procedure after STARTNET has been executed,
place the desired commands in STARTUP.BAT.\n
\n
NOTE: The AUTOEXEC.BAT will be modified in either case.
.end_help

.askkbtoauto_help
If you select YES, NETSETUP will include information to set up an LK250
keyboard in the AUTOEXEC.BAT.\n
\n 
The default LK250 keyboard setting is for US English. If you have selected
US English for your LK250, you may wish to select NO to this question to
save memory. 
.end_help

.getdosversion_help
\n
\n
Choose the version of DOS which will be running on the workstation.
.end_help

.procfinallist_help
This is the workstation profile that you just entered.\n 
\n
If you are satisfied with the values you have selected and ready to
build a key diskette with this profile, then select the "WRITE
KEY DISK" option and press Return or press the F9 key.\n 
\n
If you wish to change a value use the arrow keys to select the desired
field and press Return.  If you wish to start over press the F8 key.
.end_help

.code_page
\n
If the workstation has a code page loaded to utilize the
international character set features of SETHOST and other network
utilities, select the appropriate value. NETSETUP will append the
subdirectory with the corresponding character set files 
to the path. 
.end_help

.machine_type
Select the microprocessor/CPU of the workstation you are
configuring.  NETSETUP will choose the appropriate command to start
the DECnet Network Process, DNP, to add to STARTNET.BAT. \n
\n
If the workstation has an 8088/8086 processor it cannot utilize
extended memory.  NETSETUP, therefore, will not ask whether or not
the workstation is setup for XMS and will not allow the redirector,
REDIR, to be loaded into XMS. 
.end_help

.getvdodrv_help
\n
Select the desired video driver for your PC DECwindows Display 
Facility configuration.
.end_help

.updateorupgrade_help
\n
If you choose to upgrade your 
key diskette then the existing files: 
AUTOEXEC.BAT CONFIG.SYS will 
be backed up and not modified.  
New AUTOEXEC.BAT and CONFIG.SYS 
will be created.\n
\n
Otherwise, AUTOEXEC.BAT and 
CONFIG.SYS will be backed up and 
modified.
.end_help

.dynamicop_help
\n
MS-Windows is no longer configured with the Client.  You must use a
retail version and run the MS-Windows SETUP program to install 
it.
.end_help

.getkbmode_help
The differences between DEC mode 
and Industry Standard mode are:\n
\n
	  - In industry standard mode\n
	    the PF2/NumLock key sets the\n
	    numeric keypad mode.\n
\n
	    When the NumLock light is on, keys\n
	    function as described by the\n
	    black key legends.\n
\n
	    When the NumLock light is off, keys\n
	    function as described by the\n
	    blue key legends.\n
\n
	  - In DEC mode, the PF2/NumLock\n
	    key functions as the PF2 key only.
.end_help

.getmswinname_help
\n
Enter the directory name in which 
the MS-Windows program WIN.EXE 
resides.  This directory name will 
be included in the search path.
.end_help

.getmswinyn_help
\n
If you want to have access to 
MS-Windows in the Network, then 
select YES for this question. 
.end_help

.getmousedrv_help
\n
Select one of the mouse drivers 
in the list for the PC DECwindows Display Facility.
.end_help

.getcomport_help
\n
There is no help available for this topic at this time.\n
.end_help

.getxsvyn_help
\n
If you want to have access 
to the PC DECwindows Display Facility for MS-DOS on the 
network, select YES for the 
question.  Otherwise NO.\n
\n
Upon selection of YES, 
file DWDOS.INI initialization 
file is created and the default 
value for Maximum number of 
DECnet Logical Links is set to 
8.
.end_help

.getdecwinyn_help
\n
There is no help available for this topic at this time.\n
.end_help

.askloadcterm_help
\n
If you want to have CTERM 
protocol module to be loaded for 
wide area access to network 
command terminal, then select 
YES.
.end_help

.askloadnml_help
\n
If you want your workstation 
to be able to respond to remote 
network management command, then 
select YES.
.end_help

.askuseramdrv_help
\n
There is no help available for this topic at this time.\n
.end_help

.getnumharddsk_help
\n
There is no help available for this topic at this time.\n
.end_help

.askcountrytoauto_help
\n
If you select YES for this question, the AUTOEXEC.BAT will include
the command LCOUNTRY.\n 
\n
The default country setting for VAXmate is US English. Thus, if you
have selected US English for your VAXmate you might want to select NO
for this question to save memory. 
.end_help

****************************************************************************
 
                         N S H E L P . T X T

                        COPYRIGHT (C) 1989 BY
                DIGITAL EQUIPMENT CORPORATION, MAYNARD
                 MASSACHUSETTS.  ALL RIGHTS RESERVED

  THIS SOFTWARE IS FURNISHED UNDER A LICENSE AND MAY BE USED AND COPIED
  ONLY IN ACCORDANCE WITH THE TERMS OF SUCH LICENSE AND WITH THE INCLUSION
  OF THE ABOVE COPYRIGHT NOTICE.  THIS SOFTWARE OR ANY OTHER COPIES
  THEREOF MAY NOT BE PROVIDED OR OTHERWISE MADE AVAILABLE TO ANY OTHER
  PERSON.  NO TITLE TO AND OWNERSHIP OF THE SOFTWARE IS HEREBY TRANSFERRED.

  THE INFORMATION IN THIS SOFTWARE IS SUBJECT TO CHANGE WITHOUT NOTICE AND
  SHOULD NOT BE CONSTRUED AS A COMMITMENT BY DIGITAL EQUIPMENT CORPORATION.

  DIGITAL ASSUMES NO RESPONSIBILITY FOR THE USE OR RELIABILITY OF ITS
  SOFTWARE ON EQUIPMENT THAT IS NOT SUPPLIED BY DIGITAL.

****************************************************************************
